Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 113: 102648, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37672845

RESUMO

PURPOSE: The purpose of this study is to develop a virtual CBCT simulator with a head and neck (HN) human phantom library and to demonstrate the feasibility of elemental material decomposition (EMD) for quantitative CBCT imaging using this virtual simulator. METHODS: The library of 36 HN human phantoms were developed by extending the ICRP 110 adult phantoms based on human age, height, and weight statistics. To create the CBCT database for the library, a virtual CBCT simulator that simulated the direct and scattered X-ray on a flat panel detector using ray-tracing and deep-learning (DL) models was used. Gaussian distributed noise was also included on the flat panel detector, which was evaluated using a real CBCT system. The usefulness of the virtual CBCT system was demonstrated through the application of the developed DL-based EMD model for case involving virtual phantom and real patient. RESULTS: The virtual simulator could generate various virtual CBCT images based on the human phantom library, and the prediction of the EMD could be successfully performed by preparing the CBCT database from the proposed virtual system, even for a real patient. The CBCT image degradation owing to the scattered X-ray and the statistical noise affected the prediction accuracy, although these effects were minimal. Furthermore, the elemental distribution using the real CBCT image was also predictable. CONCLUSIONS: This study demonstrated the potential of using computer vision for medical data preparation and analysis, which could have important implications for improving patient outcomes, especially in adaptive radiation therapy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça , Adulto , Humanos , Imagens de Fantasmas , Bases de Dados Factuais , Pescoço
2.
Phys Med Biol ; 67(15)2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35738247

RESUMO

Objective.Material decomposition (MD) evaluates the elemental composition of human tissues and organs via computed tomography (CT) and is indispensable in correlating anatomical images with functional ones. A major issue in MD is inaccurate elemental information about the real human body. To overcome this problem, we developed a virtual CT system model, by which various reconstructed images can be generated based on ICRP110 human phantoms with information about six major elements (H, C, N, O, P, and Ca).Approach.We generated CT datasets labelled with accurate elemental information using the proposed generative CT model and trained a deep learning (DL)-based model to estimate the material distribution with the ICRP110 based human phantom as well as the digital Shepp-Logan phantom. The accuracy in quad-, dual-, and single-energy CT cases was investigated. The influence of beam-hardening artefacts, noise, and spectrum variations were analysed with testing datasets including elemental density and anatomical shape variations.Main results.The results indicated that this DL approach can realise precise MD, even with single-energy CT images. Moreover, noise, beam-hardening artefacts, and spectrum variations were shown to have minimal impact on the MD.Significance.Present results suggest that the difficulty to prepare a large CT database can be solved by introducing the virtual CT system and the proposed technique can be applied to clinical radiodiagnosis and radiotherapy.


Assuntos
Aprendizado Profundo , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
3.
Br J Radiol ; 94(1128): 20201236, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34541866

RESUMO

OBJECTIVES: This study aims to evaluate the accuracy of physical density prediction in single-energy CT (SECT) and dual-energy CT (DECT) by adapting a fully simulation-based method using a material-based forward projection algorithm (MBFPA). METHODS: We used biological tissues referenced in ICRU Report 44 and tissue substitutes to prepare three different types of phantoms for calibrating the Hounsfield unit (HU)-to-density curves. Sinograms were first virtually generated by the MBFPA with four representative energy spectra (i.e. 80 kVp, 100 kVp, 120 kVp, and 6 MVp) and then reconstructed to form realistic CT images by adding statistical noise. The HU-to-density curves in each spectrum and their pairwise combinations were derived from the CT images. The accuracy of these curves was validated using the ICRP110 human phantoms. RESULTS: The relative mean square errors (RMSEs) of the physical density by the HU-to-density curves calibrated with kV SECT nearly presented no phantom size dependence. The kV-kV DECT calibrated curves were also comparable with those from the kV SECT. The phantom size effect became notable when the MV X-ray beams were employed for both SECT and DECT due to beam-hardening effects. The RMSEs were decreased using the biological tissue phantom. CONCLUSION: Simulation-based density prediction can be useful in the theoretical analysis of SECT and DECT calibrations. The results of this study indicated that the accuracy of SECT calibration is comparable with that of DECT using biological tissues. The size and shape of the calibration phantom could affect the accuracy, especially for MV CT calibrations. ADVANCES IN KNOWLEDGE: The present study is based on a full simulation environment, which accommodates various situations such as SECT, kV-kV DECT, and even kV-MV DECT. In this paper, we presented the advances pertaining to the accuracy of the physical density prediction when applied to SECT and DECT in the MV X-ray energy range. To the best of our knowledge, this study is the first to validate the physical density estimation both in SECT and DECT using human-type phantoms.


Assuntos
Algoritmos , Cabeça/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Pulmão/anatomia & histologia , Pelve/anatomia & histologia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes
4.
Phys Med ; 89: 182-192, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34390901

RESUMO

PURPOSE: This study aims to estimate the proton stopping power ratio (SPR) by using 80-120 kV and 120 kV-6 MV dual-energy CT (DECT) in a fully simulation-based approach for proton therapy dose calculations. METHODS: Based on a virtual CT system, a two-step approach is applied to obtain the reference attenuation coefficient for image reconstruction. The effective atomic number (EAN) and electron density ratio (EDR) are estimated from two CT scans. The SPR is estimated using a calibration based on known materials to obtain a piecewise linear relationship between the EAN and the logarithm of the mean excitation energy, lnIm. The calibration phantoms are constructed from reference tissue materials taken from ICRU Report 44. Our approach is evaluated through using the ICRP110 human phantom. The respective influences of noise and beam hardening effects are studied. RESULTS: With the beam hardening correction applied, the results of 120 kV-6 MV DECT are comparable to those of 80-120 kV DECT in predicting the EAN, but the former demonstrated a clear improvement in predicting the EDR and SPR. The 120 kV-6 MV DECT is able to predict the SPR within an accuracy of 10% for lung tissue and 5% for pelvis tissue, thereby outperforming the 80-120 kV DECT. CONCLUSIONS: The 120 kV-6 MV DECT is less sensitive to noise but more susceptible to beam hardening effects. By applying beam hardening correction, the 120 kV-6 MV DECT can predict the SPR more accurately than the 80-120 kV DECT. To utilize our DECT approach most effectively, high-quality reconstructed images are required.


Assuntos
Terapia com Prótons , Prótons , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...